Questions 41–50 of 54. Imported answers require independent review unless marked reviewed.

Topic practice 54 questionsPage 5 of 6

Question 24

Open question
CHNAT1 markNeeds review
The liquid flow rate through an equal percentage control valve, when fully open, is 150 gal/min and the corresponding pressure drop is 50 psi. If the specific gravity of the liquid is 0.8, then the valve coefficient,

(in gal/(min psi

)) is ______ (rounded off to two decimal places).

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 30

Open question
CHMCQ2 marksNeeds review
Consider two non-interacting tanks-in-series as shown in figure. Water enters TANK 1 at

cm

/s and drains down to TANK 2 by gravity at a rate

(cm

/s). Similarly, water drains from TANK 2 by gravity at a rate

(cm

/s) where

and

represent levels of TANK 1 and TANK 2, respectively (see figure). Drain valve constant

cm

/s and cross-sectional areas of the two tanks are

cm

. At steady state operation, the water inlet flow rate is

cm

/s. The transfer function relating the deviation variables

(cm) to flow rate

(cm

/s) is,
Diagram for Chemical Engineering question 30

Your answerChoose one option.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 31

Open question
CHMCQ2 marksNeeds review
Choose the option that correctly matches the step response curves on the left with the appropriate transfer functions on the right. The step input change occurs at time

.
Diagram for Chemical Engineering question 31

Your answerChoose one option.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 49

Open question
CHNAT2 marksNeeds review
For the closed loop system shown in figure,
Diagram for Chemical Engineering question 49

the phase margin (in degrees) is __________ (rounded off to one decimal place).

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 18

Open question
CHMCQ1 markNeeds review
A first-order process having a transfer function, Gₚ = 2/(7s + 1) is controlled by a proportional controller with gain of 3.2. The process time constant is in minutes. Addition of the integral control action with an integral time constant of 5 minutes leads to increase in
Your answerChoose one option.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 31

Open question
CHMCQ2 marksNeeds review
The decay ratio for a system having complex conjugate poles as (−1/10 + j 2/15) and (−1/10 − j 2/15) is
Your answerChoose one option.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 32

Open question
CHMCQ2 marksNeeds review
Match the items in Column A with the items in Column B
Column A
Column B
(P) Pure dead-time
(I)

(Q) Pure capacitive
(II)

with

(R) Inverse response
(III)

(S) First-order process with unit gain
(IV)

Here,

denotes the phase shift,

and

the process gains,

the time constant, and AR the amplitude ratio.
Your answerChoose one option.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 44

Open question
CHNAT2 marksNeeds review
Consider the following transfer function:

where, the natural period of oscillation is in min. The amplitude ratio at a frequency of 0.5 rad/min is ____________ (rounded off to second decimal place).

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 45

Open question
CHNAT2 marksNeeds review
For a closed-loop system, consider the following transfer functions: process

, controller

, measuring device

, and final control element


The offset in the closed loop response due to a unit step change introduced in the set point of the output variable is ________.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 20

Open question
CHMCQ1 markNeeds review
Match the variables in Group-1 with the instruments in Group-2.
Group-1 P) Temperature Q) Liquid level R) Vacuum S) Concentration
Group-2 I) Capacitance probe II) McLeod gauge III) Chromatograph IV) Thermistor
Choose the correct set of combinations.
Your answerChoose one option.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer