Question 49

Open question
INNAT2 marksNeeds review
The hot junction of a bare thermocouple, initially at room temperature (30°C), is suddenly dipped in molten metal at

s. The cold junction is kept at room temperature. The thermocouple can be modeled as a first-order instrument with a time constant of 1.0 s and a static sensitivity of 10 μV/°C. If the voltage, measured across the thermocouple indicates 10.0 mV at

s, then the temperature of the molten metal in °C is ________.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 50

Open question
INNAT2 marksNeeds review
A resistance temperature detector (RTD) is connected to a circuit, as shown in the figure. Assume the opamp to be ideal. If

, then the value of

is ________.
Diagram for Instrumentation Engineering question 50


Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer

Question 51

Open question
INNAT2 marksNeeds review
The magnetic flux density of an electromagnetic flowmeter is 100 mWb/m². The electrodes are wall-mounted inside the pipe having a diameter of 0.25 m. A voltage of 1 V is generated when a conducting fluid is passed through the flowmeter. The volumetric flowrate of the fluid in m³/s is ________.

Log in to check the answer

You can attempt this question now. Sign in to view the answer key, explanations and discussion.Log in to check answer